CYTO'S SPRING COMPRESSION design is the key to higher performance. It provides a reactive spring action compensating for thermal expansion and contraction, maintaining even pressure on the cable at all times. Think of CYTOLOK®'s contribution to the complete electrical system. Connectors link expensive switch gear and costly power cables. It is critical to use CYTOLOK, the best possible connector, the VITAL LINK. SPRING COMPRESSION makes CYTOLOK superior to all other connectors. CYTOLOK, connector technology's future. Today.  
 
The Breakthrough A Spring Compression
Cable Connector
   
 
 
 

 
 
 

 

 
 

 

Cuts Costs. Cut installation
time by up to 70%.
 
Won't Back Out.Eliminates
cold flow.
  Cytolok's Spring action
compensates for thermal
expansion
automatically.
 
Vibration resistant.
Cytolok's spring action
counters
vibration - No more callbacks for
torque checks.
 
Runs Cooler by up to 14°C
than die compression
or mechanical
set screw connectors.
 
Low Electrical Resistance.
Increases connection life.
 
Short Circuit Stability.
Cytolok connectors
out perform the
cables they terminate.
 
Corrosion Resistant.
Treatedwith Cyto's
proprietary
corrosion resistant Process EC90.
 
Eliminates galvanic bimetallic
corrosion in
nearly every environment. 
Dual Rated · For copper
and aluminum cables
  UL Listed and
CSA Certified for 90°C copper or
aluminum (AL9CU). Rated up to 65kV
per independent
Corona Test.
No Special Tools.Installs
with a wrench.   No more compression
tools or torque wrenches. 
Field Proven: 15 years of
field experience.   Unbeatable
portfolio of Laboratory Tests and
Approvals.   Specification Text
available on computer disc.  
 
 
Top of the Page                                                   End of the Page

 

 
 
 
 
 
Cytolok
Multiple Position
POWER BAR
Patent Pending

  Designed to replace standard compression
lugs, CYTOLOK Power Bars drastically
reduce the time required for installation
and cable termination of three phase, pad
mounted transformers while providing
the superior reliability of "Spring
Compression". Extension spades and
compression tools are no longer needed.
CYTOLOK Power Bars become the bus bar
and are bolted onto two position, four
hole spades with the mounting hardware
provided and can be installed on either
the right or left side of the spade and in a
back-to-back configuration with just a
wrench. Available in cable sizes from 1/0
AWG thru 1,000 KCMIL.
 

 
Available in most cable sizes and
3, 4, 5, & 6 port configurations.
 



 
  

MULTIPLE PORT POWER BARSTM

Catalog #

Description

PB1020E4 1/0-2/0 AWG 3 Cable ports - 1/2" Bolts
PB1020F4 1/0-2/0 AWG 4 Cable ports - 1/2" Bolts
PB1020G4 1/0-2/0 AWG 5 Cable ports - 1/2" Bolts
PB1020H4 1/0-2/0 AWG 6 Cable ports - 1/2" Bolts
PB3040E4 3/0-4/0 AWG 3 Cable ports - 1/2" Bolts
PB3040F4 3/0-4/0 AWG 4 Cable ports - 1/2" Bolts
PB3040G4 3/0-4/0 AWG 5 Cable ports - 1/2" Bolts
PB3040H4 3/0-4/0 AWG 6 Cable ports - 1/2" Bolts
PB2530E4 250-300 MCM 3 Cable ports - 1/2" Bolts
PB2530F4 250-300 MCM 4 Cable ports - 1/2" Bolts
PB2530G4 250-300 MCM 5 Cable ports - 1/2" Bolts
PB2530H4 250-300 MCM 6 Cable ports - 1/2" Bolts
PB3540E4 350-400 MCM 3 Cable ports - 1/2" Bolts
PB3540F4 350-400 MCM 4 Cable ports - 1/2" Bolts
PB3540G4 350-400 MCM 5 Cable ports - 1/2" Bolts
PB3540H4 350-400 MCM 6 Cable ports - 1/2" Bolts
PB5060E4 500-600 MCM 3 Cable ports - 1/2" Bolts
PB5060F4 500-600 MCM 4 Cable ports - 1/2" Bolts
PB5060G4 500-600 MCM 5 Cable ports - 1/2" Bolts
PB5060H4 500-600 MCM 6 Cable ports - 1/2" Bolts
PB7050E4 700-750 MCM 3 Cable ports - 1/2" Bolts
PB7050F4 700-750 MCM 4 Cable ports - 1/2" Bolts
PB7050G4 700-750 MCM 5 Cable ports - 1/2" Bolts
PB7050H4 700-750 MCM 6 Cable ports - 1/2" Bolts
PB8010E4 800-1000 MCM 3 Cable ports - 1/2" Bolts AL Only †  
PB8010F4 800-1000 MCM 4 Cable ports - 1/2" Bolts AL Only †
PB8010G4 800-1000 MCM 5 Cable ports - 1/2" Bolts AL Only †
PB8010H4 800-1000 MCM 6 Cable ports - 1/2" Bolts AL Only †
PB1000E4 800-1000 MCM 3 Cable ports - 1/2" Bolts AL/CU **
PB1000F4 800-1000 MCM 4 Cable ports - 1/2" Bolts AL/CU **
PB1000G4 800-1000 MCM 5 Cable ports - 1/2" Bolts AL/CU **
PB1000H4 800-1000 MCM 6 Cable ports - 1/2" Bolts AL/CU **
For installations requiring more than 6 cable terminations
per Power Bar, please consult Cyto Meridian's engineering department (Tel.# 1-888-CYTOLOK or 941-369-1194).  

† For use on Aluminum cables only
** Utilizes larger Cytolok to accommodate copper conductor to NEMA 1.75" width standard

 

 

Power Bars will be shipped from the factory in protective shrink-wrap packaging with male tangs fixed in the open position, complete with mounting hardware. All Power Bars are universal and can be mounted on either the right or left side of the spade and in a back-to-back configuration. Hole spacing will be standard NEMA pattern.


Mounting hardware includes:


• Carriage bolts, with nuts and washers for closing down the Cytolok onto the cables (these will be captive to prevent loosening during shipment).

 

• Two Bellville washers with nuts and bolts for mounting the Power Bar to the top side of the spade.

 

• Two long bolts and washers to be used for closing down the Cytolok while connecting the Power Bar to the spade. These two bolts will be fastened using our unique, extension nuts, which will allow the use of shorter bolts.

 

Simply mount the Power Bar to the spade using the top two holes and the Bellville washers. If you're mounting two Power Bars on the same spade in a back-to-back configuration then you can mount them both at the same time with the bolts passing thru the spade. Inserting the cables into a Power Bar™ is much easier and a lot faster then using compression lugs and heavy tools. Simply insert the stripped cable into the Cytolok with one hand and tighten the nut with the other hand. Please note: In a back-to-back installation, the two long bolts will be used in the first two rear positions along with the special extension nuts. These bolts will pass thru the spade and close both the left and right Cytoloks at the same time.

 

 

Typical back to back Power Bar installation.

Top of the Page                                                     End of the Page

 
Transformer & Drive Manufacturers ATTENTION: ENGINEERING DEPARTMENT 
 
Do you use the above type of Winding in your Transformer or Drives? 
 
  Want to ELIMINATE BRAZING?
  Improve your technical connection!
  Reduce installation time!
 
CYTOLOK® cable connectors Eliminate Brazing and its inherent difficulties
 
Top of the Page                                                     


Back 

ADAPT New Zealand Limited.

 

184 Elgin Road ( RD7 )

Ashburton

 

Phone 03 302 3023

Fax     03 302 3093

WEB www.adaptnz.com

 

Steve Offord

Regional Manager

Mobile 021 507 831

email sofford@adaptnz.com

 

Ruth Offord

Manager Major Accounts

Mobile 021 507 832

email rofford@adaptnz.com